*NYNÍ REZERVOVÁNO NA ROK 2024* Transitmania 15 @ Santa Pod 19. až 21. července 2024 *VŠECHNY PODROBNOSTI ZDE*
heaters not blowing hot air, cold air only
Fórum Transit Mk6 a Mk7. Všechny tranzity 2000 – 2013
38 příspěvků • Stránka 1 of 3 • 1 , 2, 3
heaters not blowing hot air, cold air only
by nick-barnes07 » So 17. října 2009 5:22
hey all, my heaters on my van are not blowing hot air , they only blow cold air . i thought it was due to the egr cooler being gone but i have just had that chnaged and it is still the same!! anyone know what it could be, the van seems perfectly normal, no water inside from heater matrix, no over heating or anything
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by zimní vytápění » So 17. října 2009 5:27
you’ll have to check theres actually water circulating through the matrix first. and check water level.(look inside bottle )
under bonnet you cant miss 2 pipes ghoing through to heater matrix. if there both hot then the problems inside, and not water circulation.
zimní vytápění Transit Extremist
Příspěvky: 10872 Založen: Út 01. července 2008 10:21 pronájem: Co.Durham Darlington
Re: heaters not blowing hot air, cold air only
by bdp210 » So 17. října 2009 7:42
as the head gone at all? or blockage in pipes, or air lock?
bdp210 Transit Aficionado
Příspěvky: 261 Založen: Pondělí 04. května 2009 4:58 pronájem: Burton-upon-Trent
Re: heaters not blowing hot air, cold air only
by nick-barnes07 » So 17. října 2009 9:00
bdp210 wrote: as the head gone at all? or blockage in pipes, or air lock?
no the head hasnt gone, no blockages, and no air locks as the van would start overheating if there was air locks blockages in pipes etc etc, van is all okay, i will check the circulation pipes tommorw , i have done about 400 miles in it without a problem so wouldn’t of thought the circulation would of been an issue. it also smokes some times when on boost. the egr valve looks like a brand new one as well so isnt egr related. im thinking this could be to do with it as well
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by zimní vytápění » So 17. října 2009 9:06
nick-barnes07 wrote:
bdp210 wrote: as the head gone at all? or blockage in pipes, or air lock?
no the head hasnt gone, no blockages, and no air locks as the van would start overheating if there was air locks blockages in pipes etc etc, van is all okay, i will check the circulation pipes tommorw , i have done about 400 miles in it without a problem so wouldn’t of thought the circulation would of been an issue.
well the pipes are sized so that if the pump does fail, theres a certain amount of circulation by gravity.
flow goes to top of rad outlet at bottom.
all vehicles are like this.#
and you can of course have no water in an engine and it will not show that its overheating as theres no way the heat can get to temp sender.
zimní vytápění Transit Extremist
Příspěvky: 10872 Založen: Út 01. července 2008 10:21 pronájem: Co.Durham Darlington
Re: heaters not blowing hot air, cold air only
by nick-barnes07 » So 17. října 2009 9:18
winterheating wrote:
nick-barnes07 wrote:
bdp210 wrote: as the head gone at all? or blockage in pipes, or air lock?
no the head hasnt gone, no blockages, and no air locks as the van would start overheating if there was air locks blockages in pipes etc etc, van is all okay, i will check the circulation pipes tommorw , i have done about 400 miles in it without a problem so wouldn’t of thought the circulation would of been an issue.
well the pipes are sized so that if the pump does fail, theres a certain amount of circulation by gravity.
flow goes to top of rad outlet at bottom.
all vehicles are like this.#
and you can of course have no water in an engine and it will not show that its overheating as theres no way the heat can get to temp sender.
water level is at maximum and has been for last few days since having the egr cooler sorted.
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by nick-barnes07 » Ne 18. října 2009 2:30
anyone know if it could be a heater control valve , do the transits have heater control valves like other fords. one of these i meanhttp://cgi.ebay.co.uk/HEATER-CONTROL-VA . 3ef8d6f046
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by zimní vytápění » Ne 18. října 2009 2:32
have you checked theres flow through heater yet takes about 2 seconds, not including openining the bonnet.
zimní vytápění Transit Extremist
Příspěvky: 10872 Založen: Út 01. července 2008 10:21 pronájem: Co.Durham Darlington
Re: heaters not blowing hot air, cold air only
by nick-barnes07 » Ne 18. října 2009 3:30
got the van running now, the bottom and top radiator pipe is stone cold. and the engine is at normal temparature , the pipe under the coolant bottle is hot so there is water going through the pipe coming out of the bottle and either side of the thermostat just not the top and bottom rad pipes, will the rad need flushing.
Last edited by nick-barnes07 on Sun Oct 18, 2009 4:29 pm, edited 3 times in total.
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by bdp210 » St 21. října 2009 5:02
sounds like stat problem
bdp210 Transit Aficionado
Příspěvky: 261 Založen: Pondělí 04. května 2009 4:58 pronájem: Burton-upon-Trent
Re: heaters not blowing hot air, cold air only
by zimní vytápění » St 21. října 2009 9:18
bdp210 wrote: sounds like stat problem
if the main stat was stuck open the engine would prob never get up to working temp, and blowers would be just warm.
sounds like stat and rad are fine, but not circulation.
zimní vytápění Transit Extremist
Příspěvky: 10872 Založen: Út 01. července 2008 10:21 pronájem: Co.Durham Darlington
Re: heaters not blowing hot air, cold air only
by nick-barnes07 » Čt 22. 2009. 9 00:XNUMX
bit of a weird one, i think it may be a bit more indepth than i know of, i am going to get it booked into ford’s when i get payed and get them to have a look at it,
nick-barnes07 Transit Aficionado
Příspěvky: 228 Založen: St 10. prosince 2008 5:59
Re: heaters not blowing hot air, cold air only
by 100 T280 » Čt 22. 2009. 11 18:XNUMX
nick-barnes07 wrote: anyone know if it could be a heater control valve , do the transits have heater control valves like other fords. one of these i meanhttp://cgi.ebay.co.uk/HEATER-CONTROL-VA . 3ef8d6f046
Only with A/C.
What Mk, and has it got A/C? With A/C, temperature selection is controlled by stepper motor on blend door, and these can stop working, sticking on last position regardless of temperature selector knob.
’02 100 T280 SWB Exec. FWD Medium Roof 2.0 DuraTorq TDdi 100ps
College Blue , Alloys , Eberspächer , Twin Batteries , Single Seat ,
«Park Distance Control», AirCon , Rev. Counter , 7000RDS .
100 T280 Transit Devotee
Příspěvky: 1498 Založen: Út 23. května 2006 11:10 pronájem: Midlands
Re: heaters not blowing hot air, cold air only
by alexgrfc » Čt 22. 2009. 11 38:XNUMX
change the thermostat it takes 10 mins ,worth a try
Transit t260 100
********** visit my blog @ http://www.transitpics.co.uk// **********
http://www.scottish-vanners.co.uk
alexgrfc Transit Devotee
Příspěvky: 677 Založen: St 04. února 2009 7:48 pronájem: Glasgow
Re: heaters not blowing hot air, cold air only
by zimní vytápění » Čt 22. 2009. 11 56:XNUMX
nick-barnes07 wrote: bit of a weird one, i think it may be a bit more indepth than i know of, i am going to get it booked into ford’s when i get payed and get them to have a look at it,
whys it weird one, the stat and rad are working correctly,
if both top and bottom were same temp it would show water pump is working but stat fully open, its not that.
if it over heated and blowers work and rad is cold, it would show main stat stuck shut, its not that
if it didnt over heat, flow through rad was ok, dont have circulation of water through blowers, it means. stat is working ok and cooling is working by gravity through rad but water pump isnt working fully
zimní vytápění Transit Extremist
Příspěvky: 10872 Založen: Út 01. července 2008 10:21 pronájem: Co.Durham Darlington