Are your vents blowing out cold air when your heater is on? Here are several possible reasons why.
By Rick Overall, HVAC Manager at Frymire Home Services
10:03 AM on Jan 26, 2021 CST
During the winter season, having cold air coming out of your vents is the last thing you want happening when you turn on your heater. Within your AC system, you have four main units: your condenser (located outside your home), your coil (located inside your home), your furnace (located inside your home), and your thermostat (located inside your home). The thermostat is probably the unit you are most familiar with, as this is what you use to regulate the temperature within your home.
Essentially, your AC system does one of two things for you: it is either bringing hot air into your home by heating or it is taking the hot air out of your home by cooling. Your condenser, coil, furnace and thermostat work together to make this happen.
There can be nothing more puzzling than experiencing cold air coming through your vents instead of the hot air you are wanting, but at Frymire Home Services, we’re here to bring you peace of mind. Here are six possible reasons why your vent is blowing out cold air instead of hot air.
The first reason could be due to the age of your flame sensor.
Sledujte novinky dne, které potřebujete vědět.
Registrací souhlasíte s našimi Podmínkami služby a Zásadami ochrany osobních údajů
Your flame sensor is located within your furnace and is an important safety feature that not only protects your unit, but also protects you. When a flame is ignited within your furnace, your flame sensor makes sure to burn the natural gas to continue the heating cycle. When no flame is detected, your flame sensor automatically shuts off your furnace, ensuring that no natural gas escapes into your unit. As your furnace ages, so does your flame sensor. The only two ways to fix this would be having your flame sensor cleaned or having it replaced.
The second reason could be due to a bad limit switch.
Your limit switch is located inside your home and is attached to your furnace. When the heat exchanger becomes too hot, your limit switch acts as a safety mechanism and turns off the burner. Problems arise when your limit switch malfunctions and either continuously runs your blower (which never properly ends a heating cycle) or it will not allow your furnace to operate because it is continuously turning off the burner. To fix this, you will need to have a technician come out and diagnose the underlying issue. It could be as simple as making sure that your filters and fan blades are cleaned properly or making sure that there is no improper duct sizing or high static pressure. In the end, you might have to have your limit switch replaced.
The third reason could be due to a faulty fan or motor.
Within your furnace, you have your blower fan and your inducer draft motor. Your indoor fan, otherwise known as the “blower,” is responsible for bringing in hot air when in heating mode. The reason this can go out is because the blower has reached its lifespan, has had inadequate duct work, or has high static pressure. Two ways to fix this would be to either lower the static pressure, or if that does not work, replace it with a newer one.
Next, you have your inducer draft motor, which is responsible for removing exhaust gas. The reason this becomes faulty is because it has a restriction or blocked flu pipe, or the windings have burned up. To fix this, you would need to have the blockage or restrictions cleared, or if that does not work, have the motor replaced.
The fourth reason could be due to the age of your gas valve.
Your gas valve is located outside your furnace and is what opens and closes the furnace’s fuel system. When you tell your thermostat to heat, your furnace’s gas valves begin to open and close and allow the gas to flow to the pilot light and burner(s). When the gas valve stops working properly, the only way this can be fixed is by replacing it with a newer one.
The fifth reason could be a low refrigerant charge in your AC system.
This issue happens due to a leak in either your heat pump or coil, and can be fixed by having a technician locate the leak and repair the leak. If the leak cannot be repaired, you will need to replace your AC system with a newer one. This would only be applicable if you have a heat pump system.
The sixth reason could be due to a bad compressor.
The compressor is inside your heat pump, located outside your home. The compressor is the heart of your AC system and is what keeps everything running smoothly. When this goes out, you will need to replace it. Some reasons compressors go out could be because it was over or under charged, had a faulty run capacitor, a faulty motor, a dirty evaporator and coil, dirty condensing coils, or had under sized duct work. Again, this is only applicable in heat pump systems.
Frymire Home Services understands the importance of educating and informing our customers and helping them become air conditioning experts! We make sure that we not only correct your issue, but also help you understand why the issue happened. To learn more about your air conditioning system, visit us online or call us at 214-296-2663 to schedule an appointment with one of our licensed technicians.
Zapnutí klimatizace pouze za účelem zjištění, že systém nedokáže foukat chladný vzduch, patří mezi nejběžnější typy problémů s HVAC v domácnostech. Pokud vás zajímá, co tuto poruchu způsobuje, Bloomington Heating & Air nabízí pět hlavních důvodů AC nefouká studený vzduch. Pokud vaše klimatizace nefunguje správně, zavolejte nám Firma na opravy HVAC — Poskytujeme okamžitou a účinnou 24hodinovou nouzovou opravu střídavého proudu, takže nikdy nebudete muset snášet horké podmínky nebo čekat na běžnou pracovní dobu, abyste získali chladnou úlevu. Naplánujte si služby HVAC ještě dnes.
Pět důvodů, proč vaše klimatizace běží, ale nefouká studený vzduch
Pokud se klimatizace úplně porouchá, je zřejmé, že systém vyžaduje okamžitou odbornou péči. Selhání systému HVAC však není jediným okamžikem, kdy zavolat naše techniky AC oprava. Pokud váš Klimatizace běží, ale nefouká studený vzduch, může to být důsledkem následujících pěti běžných problémů. Kontaktujte nás ještě dnes a promluvte si s vyškoleným technikem o vašem systému.
1. Ucpané vzduchové filtry
Kdy jste naposledy měnili vzduchové filtry u vás doma? Pokud si nepamatujete – nebo pokud jste je nikdy neměnili – je pravděpodobné, že vzduchové filtry jsou ucpané nečistotami ve vzduchu, znečišťujícími látkami a nečistotami, které se v průběhu času hromadí. Pokud jsou vzduchové filtry znečištěné nebo ucpané, brání proudění studeného vzduchu ze systému HVAC. Znečištěný vzduchový filtr zabraňuje proudění nasávaného vzduchu klimatizací, což brání systému v dostatečném chlazení domácnosti. Vzduchové filtry vyžadují výměnu několikrát v průběhu roku – registrace do našeho programu plánované údržby HVAC pro domácnosti zahrnuje služby čištění a výměny filtrů, mezi řadu dalších služeb, které udrží váš systém ve špičkovém stavu.
2. Nesprávné nastavení termostatu
Pokud klimatizace dostatečně nechladí nebo pokud vůbec nefouká studený vzduch, může to být způsobeno nesprávným nastavením termostatu. Nastavení ventilátoru na «AUTO» pomůže snížit náklady na měsíční poplatky, ale může také způsobit, že systém bude vzduch cyklovat, místo aby jej ochlazoval. Naproti tomu nastavení termostatu do režimu «ON» způsobí, že systém běží 24/7, což by mělo obnovit proudění chladného vzduchu. Pokud termostat neukazuje vůbec nic, možná budete muset vyměnit baterie nebo se může jednat o elektrický problém – v tomto případě zavolejte odborníka, aby to vyřešil. Pokud potřebujete vyměnit termostat, můžeme vám pomoci vybrat si mezi termostaty bez Wi-Fi a termostaty Wi-Fi na základě vašich preferencí a požadavků.
3. Nedostatečný průtok vzduchu
Pokud ventilačními otvory neprochází dostatek vzduchu, nezáleží na tom, jak chladný vzduch klimatizací protéká. Ať už systémem proudí malé množství studeného vzduchu nebo žádný studený vzduch, problém může být způsoben ucpanými nebo ucpanými větracími otvory, což má za následek nedostatečné proudění vzduchu. Zkontrolujte větrací otvory v celém domě a ujistěte se, že jsou všechny otevřené. Při kontrole každého větracího otvoru zkontrolujte, zda vnitřní část větracího otvoru není ucpaná nečistotami a jinými nečistotami. Pokud jsou větrací otvory ucpané a nedaří se vám odstranit nečistoty, zavolejte nám na opravu HVAC. Naši technici mohou provést čištění potrubí a zkontrolovat ventilátor AC na případné problémy.
4. Elektrické problémy
Nedostatek studeného vzduchu může být stejně jednoduchý problém jako vypnutý jistič. Vaše klimatizace se připojuje ke dvěma jističům – jednomu pro vnější a druhému uvnitř domu. Pokud se vypne vnější jistič a vnitřní jistič stále funguje, vzduch nelze ochladit. Resetujte jistič, abyste zjistili, zda je obnoven proud studeného vzduchu. Pokud ventilačními otvory neproudí studený vzduch, zavolejte odborníka, aby problém prověřil. Následné resetování jističe by mohlo způsobit poškození AC.
5. Je nutná výměna HVAC
Pokud vlastníte svůj současný chladicí systém déle než 10 až 15 let, nedostatek studeného vzduchu může být způsoben potřebou výměny systému HVAC. Když klimatizace dosáhne konce své funkční životnosti, pravděpodobně nebude schopna chladit jako při první instalaci. Naši technici mohou systém zkontrolovat, aby vám pomohli určit nejlepší typ náhrady pro vaši domácnost. Nabízíme bezproblémové instalace klimatizace pomoci obnovit váš domov chladným vzduchem během okamžiku.
Bloomington topení a vzduch
1101 West 80th St.,
Bloomington, MN 55420
Copyright © 2024 Bloomingtonheating.com — Všechna práva vyhrazena